ATG for Liquid LPG storage tank under normal temperature LPG ATG system consist :
1. Measure LPG level, temperature and ullage; all data can be stored according to need
2. Up to 16 tanks
3. Monitor delivery and generate report
4. High level and low level alarm
5. Inventory data and alarm can be uploaded to other systems
PLS-5BX Probe for LPG:
Platform based Cloud and link to smart phone:
Features & Benefits:
Items | Spec. | Items | Spec. | ||||||||||||
Measured Variable |
LPG | Probe casing pipe | Stainless steel tube (model: 316) | ||||||||||||
Power | 24V (dc) special safety barrier | Installation |
Add probe installation riser with blind flange |
||||||||||||
Output signal | RS485, digital | Anti-interference |
Anti-electromagnetic interference Surge handling capability |
||||||||||||
Protocol | Exclusive | Explosion-proof grade | Ex ia IIBT4 Ga | ||||||||||||
Baud rate | ≥9600 | Probe Protection Degree | IP68 | ||||||||||||
Metering range |
Probe pipe: ≤4m ; liquid lower dead zone: ≤44 mm |
Pressure | -0.015 to 0.2 MPa | ||||||||||||
Accuracy | ±0.5mm | Temperature | - 40°C~+70°C | ||||||||||||
Temperature Accuracv | ±0.2℃ | Max Communication Distance | 1200m | ||||||||||||
Product Resolution | ±0.001mm | Communication | Console/Other system | ||||||||||||
Water Resolution | ±0.001mm | Float | Special LPG float | ||||||||||||
Temperature sensor | 5 | Float working pressure | ≤3Mpa | ||||||||||||
Temperature Resolution | ±0.06℃ | Float size | 2inch |