1.CSLS-1 Manhole Leak Detection Sensor(discriminating)
CSLS-1 manhole leak detection sensor is used to monitor whether liquid exits in the manhole. Two alarm points are set to monitor the liquid level and it can distinguish the liquid is water or fuel. Self-detection function can detect open circuit or short circuit.
Functions:
● Two alarm points to detect liquid level
● Fuel alarm
● Short alarm
● Open alarm
● Can detect the hydrocarbon on the water, and trigger fuel alarm
Parameters:
● Temperature: -40℃~60℃(fuel); 0℃~60℃(no freezing water)
● Length of sensor cable: 2m
● Specifications: Length: 545mm; Diameter: 55mm
● Water alarm point: 28mm; 285mm
● Minimum alarm level: 4mm
● Minimum fuel film thickness on water: 1mm
● Sensor accuracy: ≤2mm
● Enclosure protection class: IP68
Installation Diagram:
2.CSLS-2C Manhole Leak Detection Sensor
CSLS-2C manhole leak detection sensor is used to monitor whether liquid exits in the manhole. Self-detection function can detect open circuit or short circuit.
Functions:
● liquid exits alarm
● Short alarm
● Open alarm
Parameters:
● Temperature: -40℃~60℃(fuel); 0℃~60℃(no freezing water)
● Length of sensor cable: 2m
● Specifications: Length: 545mm; Diameter: 55mm
● Sensor accuracy: ≤2mm
● Enclosure protection class: IP68
Installation Diagram: